-
Nissen McCurdy posted an update 10 months, 2 weeks ago
In-line X-ray phase-contrast computed tomography (IL-PCCT) can produce high-contrast and high-resolution images of biological samples, and it has a great advantage with regard to imaging the microstructures and morphologies of fibrous biological tissues (FBTs). Filtered back projection (FBP) is widely used in ILPCCT. However, it requires long scanning times and high radiation doses to produce high-quality CT images, and this restricts its applicability in biomedical and preclinical studies on FBTs. To solve this problem, a novel IL-PCCT reconstruction algorithm is proposed to decrease the radiation dose by reducing the number of projections and reconstruct high-quality CT images of FBTs. The proposed algorithm incorporates the FBP method into the iterative reconstruction framework. Considering the area types and anisotropic edge properties of FBTs, a discriminant adaptive-weighted total variation model is introduced to optimize the intermediate reconstructed images. A fibrous phantom simulation and real experiment were performed to assess the performance of the proposed algorithm. Simulation and experimental results demonstrated that the proposed algorithm is an effective IL-PCCT reconstruction method for FBTs with incomplete projection data, and it has a great ability to suppress artifacts and preserve the edges of fibrous structures.Polarization imaging is a powerful tool, which can be applied in biomedical diagnosis and many research fields. Here, we propose a new application of the indices of polarimetric purity (IPPs) composed of P1, P2, P3, to describe the glucose concentrations (GC) changes in the scattering system. The results suggest that P1 of the IPPs is a better indicator to GC in the solution than the degree of polarization (DoP) for the forward scattering detection. GSK2656157 mw Meanwhile, the fitting relation among radius of scattering particle, GCs and P1 parameter has also been calculated, in which the error of inversion is no more than 4.73%. In the backscattering detection, the fitted frequency statistical histogram of the IPPs is used to measure the GCs, and their modes can represent changing trend of GCs.This ex vivo study was conducted to assess the potential of using a fibre optic probe system based on autofluorescence and diffuse reflectance for tissue differentiation in the brain. A total of 180 optical measurements were acquired from 28 brain specimens (five patients) with eight excitation and emission wavelengths spanning from 300 to 700 nm. Partial least square-linear discriminant analysis (PLS-LDA) was used for tissue discrimination. Leave-one-out cross validation (LOOCV) was then used to evaluate the performance of the classification model. Grey matter was differentiated from tumour tissue with sensitivity of 89.3% and specificity of 92.5%. The variable importance in projection (VIP) derived from the PLS regression was applied to wavelengths selection, and identified the biochemical sources of the detected signals. The initial results of the study were promising and point the way towards a cost-effective, miniaturized hand-held probe for real time and label-free surgical guidance.In this study, we developed a novel phase-stabilized complex-decorrelation (PSCD) optical coherence tomography (OCT) angiography (OCTA) method that can generate high quality OCTA images. This method has been validated using three different types of OCT systems and compared with conventional complex- and amplitude-based OCTA algorithms. Our results suggest that in combination with a pre-processing phase stabilization method, the PSCD method is insensitive to bulk motion phase shifts, less dependent on OCT reflectance than conventional complex methods and demonstrates extended dynamic range of flow signal, in contrast to other two methods.Percutaneous renal access is the critical initial step in many medical settings. In order to obtain the best surgical outcome with minimum patient morbidity, an improved method for access to the renal calyx is needed. In our study, we built a forward-view optical coherence tomography (OCT) endoscopic system for percutaneous nephrostomy (PCN) guidance. Porcine kidneys were imaged in our experiment to demonstrate the feasibility of the imaging system. Three tissue types of porcine kidneys (renal cortex, medulla, and calyx) can be clearly distinguished due to the morphological and tissue differences from the OCT endoscopic images. To further improve the guidance efficacy and reduce the learning burden of the clinical doctors, a deep-learning-based computer aided diagnosis platform was developed to automatically classify the OCT images by the renal tissue types. Convolutional neural networks (CNN) were developed with labeled OCT images based on the ResNet34, MobileNetv2 and ResNet50 architectures. Nested cross-validation and testing was used to benchmark the classification performance with uncertainty quantification over 10 kidneys, which demonstrated robust performance over substantial biological variability among kidneys. ResNet50-based CNN models achieved an average classification accuracy of 82.6%±3.0%. The classification precisions were 79%±4% for cortex, 85%±6% for medulla, and 91%±5% for calyx and the classification recalls were 68%±11% for cortex, 91%±4% for medulla, and 89%±3% for calyx. Interpretation of the CNN predictions showed the discriminative characteristics in the OCT images of the three renal tissue types. The results validated the technical feasibility of using this novel imaging platform to automatically recognize the images of renal tissue structures ahead of the PCN needle in PCN surgery.Swept source optical coherence tomography (SS-OCT) enables volumetric imaging of subsurface structure. However, applications requiring wide fields of view (FOV), rapid imaging, and higher resolutions have been challenging because multi-MHz axial scan (A-scan) rates are needed. We describe a microelectromechanical systems vertical cavity surface-emitting laser (MEMS-VCSEL) SS-OCT technology for A-scan rates of 2.4 and 3.0 MHz. Sweep to sweep calibration and resampling are performed using dual channel acquisition of the OCT signal and a Mach Zehnder interferometer signal, overcoming inherent optical clock limitations and enabling higher performance. We demonstrate ultrahigh speed structural SS-OCT and OCT angiography (OCTA) imaging of the swine gastrointestinal tract using a suite of miniaturized brushless motor probes, including a 3.2 mm diameter micromotor OCT catheter, a 12 mm diameter tethered OCT capsule, and a 12 mm diameter widefield OCTA probe. MEMS-VCSELs promise to enable ultrahigh speed SS-OCT with a scalable, low cost, and manufacturable technology, suitable for a diverse range of imaging applications.